texcote squareslogo

Home

Free Estimate

DeHaven Construction Company

"Specializing in Windows, Texcote™ Textured Coating and Patio Covers"

DeHaven Construction Company provides home and commercial improvements in Orange County, California. Painting, vinyl replacement windows & doors, roofing, teck deck, texture coating, stucco, vinyl fencing, patio covers.


Vinyl replacement windows by CertainTeed

Thermal Performance

Vinyl replacement window standard glazing:

double pane insulating glass is superior to the combination of prime and storm windows.

Vinyl replacement window optional glazing:

CertainTeed vinyl replacement windows can be made with a variety of special glazing systems. CertainTeed's proprietary Thermaflect Low "E" glazing offers the best thermal performance in its class. In winter, it reflects your heat back inside to help lower heating costs. In summer, it reflects outside heat to help lower cooling costs. It blocks damaging ultra violet light, while transmitting visible light - without distorting the view.

Tests show CertainTeed vinyl replacement windows with Thermaflect glass offer industry leading thermal performance.

Glazing Type Total Unit U values Center of glass U value Daylight transmittance UV block Shading coefficient
Double Hung Glider Picture Casement Awning
Ordinary double pane 0.48 0.48 0.48 0.45 0.44 0.49 0.82 42% 0.91
Low "E" Hard coat 0.39 0.39 0.37 0.37 0.36 0.35 0.75 53% 0.84
Low "E" Hard coat with Argon 0.36 0.36 0.33 0.34 0.34 0.31 0.75 53% 0.84
Low "E" Hard coat with Argon and low conductance spacer 0.35 0.34 0.32 0.33 0.32 0.31 0.75 53% 0.84
Thermaflect 0.36 0.36 0.33 0.34 0.33 0.31 0.72 85% 0.51
Thermaflect with Argon 0.33 0.36 0.33 0.34 0.33 0.31 0.72 85% 0.51
Thermaflect with Argon and low conductance spacer 0.31 0.30 0.27 0.29 0.29 0.25 0.72 85% 0.51

Notes on above chart:

Total vinyl replacement windows U values are tested in accordance with NFRC 100-91. Data based on double strength, double pane glass with a 5/8" air space. All values are for AA window size. Low conductance spacer used in test was Tremco's Swiggle Strip. Center of glass U values were supplied by glass manufacturers.

Daylight transmittance calculations have been performed using the Lawrence Berkeley Laboratories new and improved Window 4.0 computer program. UV block based on UV transmission from 300 to 380 nm. Shading coefficient summertime performance based on ASHRAE Standards of a solar heat gain factor of 200BTU/hr/ft2 and outdoor air temperature 14 degrees F warmer than indoor temperature.

Glossary of high performance glazing terms

U Value: The rate of heat flow through a glazing system; the lower the value, the better the insulating quality. U value can be compared to R value by dividing 1 by the U value. Thus, a U value of 0.5 equals an R value of 2.

Low "E": Low emissivity glass is coated with a microscopically thin metallic layer that allows short wave light to pass through by reflecting long wave heat energy.

Daylight transmittance: Measures the amount of visible light that is transmitted through the glass.

UV block: Measures the amount of damaging ultraviolet light that is blocked from being transmitted through the glass. CertainTeed vinyl replacement windows have a thermal rating of 85% (85% of UV is blocked).

Shading coefficient: Measures how much glazing material transmits heat gain compared to 1/8" glass, which is given a value of 1. Thermaflect's rating of 0.51 means that Thermaflect reduces unwanted radiation by 49%.

Weather Resistance

  • Factory sealed frames and fusion welded sashes: create a structurally strong unit that resists weather.
  • Integral glazing system: bonds glass to sash, creating a weatherproof seal.
  • Leak resistance: meets industry standards for water performance requirements for residential windows - i.e., no leakage.
  • Air infiltration: exceeds industry standard thermal window specifications as much as six times - depending upon vinyl replacement window style.
  • Drainage: sloped sill designs for double hung, casement, and awning windows; engineered weep systems for gliders.

Security and Ease of Use

  • Cam type lock and keeper: propriety design of locks pulls sashes tight for a weatherproof seal and makes it virtually impossible to open the windows from outside.CertainTeed vinyl replacement windows meet the requirements of CAWN 301-90 forced entry resistance test.
  • Night vent: provides added security while allowing ventilation.
  • Constant force balance system: For easy opening of double hung windows. This unique stainless steel balance system won't fail of corrode - tested to 10,000 cycles.
  • Safe and simple cleaning: with easy release of the tilt latches, double hung window sashes lift out, and casement windows are specially hinged for easy access to the outside surface.
  • High quality hardware: Visible hardware is made of a proprietary blend of UV stabilized engineering plastic, color matched to vinyl profiles. Fasteners, screws, and accessories are high quality stainless steel, PVC, and engineered plastics.
  • Meets or exceeds standard building code requirements: Tested in compliance with A.S.T.M. fire and smoke test procedures. A.S.T.M. E-84: Flame spread-15 fuel contribution-0; smoke density-330. A.S.T.M. D1929: Minimum self ignition temperature 979 degrees F. A.S.T.M. D635: Average time of burning = 5 seconds; average length of burning = 10 mm.

  Click here for more on High Performance glazing system

Or you can click on blue highlighted links on the right for other products and services

 

Contact us for a free estimate

Call us at: (800) 933 9737, (714) 647-2339 California only

Serving Orange County, California since 1987

Send comments about this site to: info@dehavenconstruction.com